Next: Write Block with Up: FASTBUS I/O Instruction Previous: Write Random Indirect

Write Block with a Word Count

The second operand address points to a parameter list containing the following 2 parameter(s):

  1. Word Count
  2. Starting address of the block

The block is terminated normally by exhausting the word count.



Next: Write Block with Up: FASTBUS I/O Instruction Previous: Write Random Indirect


A.Daviel,TRIUMF