Next: D Data Encoding Up: iii Operation Previous: B Skirt and MPW


C Control Register

A control register provides the following functions: Disable Pedestal, Disable Threshold, Test Mode, Enable Empty Channel and Channel Disable. The Disable Pedestal and Disable Threshold bits would typically be used to obtain raw data sets from which pedestal values could be calculated. Channel Disable allows a channel to be turned off. Enable Empty Channel creates a channel header even if there is no data in that channel. Test Mode is used for online testing of the module.



Next: D Data Encoding Up: iii Operation Previous: B Skirt and MPW



A.Daviel,TRIUMF